DEC RK05 Notes

Apologies for the rough nature of this page. In it’s present state, this page just captures notes from my attempts to get some RK05 drives working on my PDP-11/34

Really Basic Stuff

  • Inside the RK05, check the lever switch is in the UP position
  • Under RT11, the RK05 shows up as RKn: (ie RK0:, RK1:, etc)
  • When a cartirdge is loaded (and the PDP-11 is turned on) the PWR, RDY and ONCYL lights will be on
  • ONCYL seems to indicate that the drive is NOT seeking (ie it does not mean “on cylinder 0”)

RK05B S/N WF8032

I started working on this drive in June 2021.

This is the drive that was in the Industrial 8 H967 cabinet. It needs new rubber isolation mounts.

PAKs don’t always sit properly on the right-hand pin support.

Front panel uses bulbs. All checked/replaced in June 2021. Lovely and bright.

I’ve been able to initialise, read and write 2 RK05 cartridges with this drive. However, over time they have deteriorated and one of them now has bad blocks in the system area and can’t be used.

However, on 27/7/21 I decided to INIT/BADBLOCKS a 3rd pack. It did lots of seeking during the INIT process, but reported 0 bad blocks. I was then able to install date-patched RT-11 5.3 on to it from DX0. That worked well, and it boots without error. This 3rd PAK has been reserved to use exclusively with this drive.