{"id":1983,"date":"2017-05-15T23:52:33","date_gmt":"2017-05-15T23:52:33","guid":{"rendered":"http:\/\/avitech.com.au\/?page_id=1983"},"modified":"2017-05-16T00:32:46","modified_gmt":"2017-05-16T00:32:46","slug":"dec-microvax-3600","status":"publish","type":"page","link":"https:\/\/avitech.com.au\/?page_id=1983","title":{"rendered":"DEC MicroVAX 3600"},"content":{"rendered":"<p>This page captures what I have discovered so far in bringing up two MicroVAX 3600s.<\/p>\n<p>As of 16 May 2017, I have only attempted to bring up one of the two 3600s. This one is a fairly ugly looking unit. It&#8217;s clearly been stored outdoors for some part of its life. It has leaf, rodent and corrosion damage inside the rear of the cabinet, as well as significant fading and disclouration of the front door. The machine has two RA90 drives mounted at the top of the cabinet. However, these have been fitted in a fairly amateurish manner (for example &#8211; there is no front panel in front of the two RA90s).<\/p>\n<p>After thoroughly cleaning up this 3600, I was very surprised to find that it successfully booted up into VMS 5.5 from the left-hand RA90 on the very first attempt!  Both RA90s initially squealed slightly for about the first 10 minutes, but the noise went away after that and they&#8217;ve been fine since. It sounded a little like fan-belt slip, though it was more likely to be bearing noise (I&#8217;ve been told there are no drive belts in the RA90 drives).<\/p>\n<h4>13 May 2017<\/h4>\n<p>I first powered up this 3600 on 13 May 2017. By issuing the &#8220;boot&#8221; command at the &#8220;>>>&#8221; prompt, it booted into VMS 5.5.  I did not know the password for the SYSTEM account, so I was not able to progress much past this point.<\/p>\n<p>The right-hand RA90 would not spin up (the Test light would light briefly, before going out and the Fault light coming on instead).  <\/p>\n<h4>15 May 2017<\/h4>\n<p>Using the procedure outlined <a href=\"http:\/\/h41379.www4.hpe.com\/openvms\/journal\/v1\/atw.html?jumpid=reg_R1002_USEN\" target=\"_blank\">here<\/a>, I was able to break into VMS and change the password for the SYSTEM account to MICROVAX.<\/p>\n<p>The main steps taken to break into VMS and change the password are shown below:<\/p>\n<pre>\r\n>>> B\/R5:40000001\r\n\r\nSYSBOOT> SET\/STARTUP OPA0:\r\nSYSBOOT> SET WINDOW_SYSTEM 0\r\nSYSBOOT> SET WRITESYSPARAMS 0\r\nSYSBOOT> CONTINUE\r\n\r\n$ DEFINE\/SYSTEM\/EXEC DECW$IGNORE_WORKSTATION TRUE\r\n$ SPAWN\r\n$ @SYS$SYSTEM:STARTUP\r\n\r\n$ SET DEFAULT SYS$SYSTEM:\r\n$ RUN SYS$SYSTEM:AUTHORIZE\r\nUAF> MODIFY SYSTEM \/PASSWORD=newpassword\r\nUAF> EXIT\r\n$\r\n<\/pre>\n<p>When we then logged in using the SYSTEM account and the new password, VMS informed us that the last login was in 1996!<\/p>\n<p>Richard swapped a spare set of RA90 controller boards into the right-hand RA90 drive, and it now spins up and the Ready light comes on. I&#8217;ve not yet figured out how to access this drive within the VMS file system.<\/p>\n<p>The NICAD battery pack was removed from both 3600s.  Some minor corrosion was already evident, but not severe.<\/p>\n<h4>Next steps<\/h4>\n<p>Need to learn how to navigate to the second RA90 drive, to explore its contents.<\/p>\n<p>Need to repair the rotary boot-selection switch (the tiny knob has broken off).<\/p>\n<p>Need to source a replacement NICAD battery pack.<\/p>\n<h4>Links<\/h4>\n<p><a href=\"http:\/\/www.ext.zx.net.nz\/computers\/dec\/microvax3500\/docs\/\" target=\"_blank\">MicroVAX 3500 documentation<\/a> (not MicroVAX 3600, but close)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>This page captures what I have discovered so far in bringing up two MicroVAX 3600s. As of 16 May 2017, I have only attempted to bring up one of the two 3600s. This one is a fairly ugly looking unit. It&#8217;s clearly been stored outdoors for some part of its life. It has leaf, rodent ..<\/p>\n<div class=\"clear-fix\"><\/div>\n<p><a href=\"https:\/\/avitech.com.au\/?page_id=1983\" title=\"read more...\">Read more<\/a><\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1983","page","type-page","status-publish","hentry"],"jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/P7xTsk-vZ","jetpack-related-posts":[{"id":3623,"url":"https:\/\/avitech.com.au\/?page_id=3623","url_meta":{"origin":1983,"position":0},"title":"Garage Sale on Sat 5 October 2019","author":"malcolm","date":"30-September-2019","format":false,"excerpt":"I'm doing something of a clean out of vintage computer gear, due to downsizing. This Saturday (5 October 2019) from 9am to 5pm. Factory 71, 22 Dunn Crescent, Dandenong Here's a partial list of what will be available (this list will be updated on Friday): The Free Pile DEC Networking\u2026","rel":"","context":"Similar post","block_context":{"text":"Similar post","link":""},"img":{"alt_text":"","src":"","width":0,"height":0},"classes":[]},{"id":2036,"url":"https:\/\/avitech.com.au\/?page_id=2036","url_meta":{"origin":1983,"position":1},"title":"Links &#8211; DEC related","author":"malcolm","date":"24-May-2017","format":false,"excerpt":"This page is just a collection of links relevant to DEC computers and equipment. Identifying DEC Boards www.pdp-8.org's \"list of 8\/10\/11 M-series cards\" www.pdp-8.org's \"Index to mostly OMNIBUS cards\" DEC Option List and Module List (on the Internet Archive: 232 Pages) Bitsaver's directory containing Options List and Modules Lists Doug\u2026","rel":"","context":"Similar post","block_context":{"text":"Similar post","link":""},"img":{"alt_text":"","src":"","width":0,"height":0},"classes":[]},{"id":1439,"url":"https:\/\/avitech.com.au\/?page_id=1439","url_meta":{"origin":1983,"position":2},"title":"DEC 871B Power Controller","author":"malcolm","date":"26-December-2016","format":false,"excerpt":"The 871B Power Controller is a single-phase 240VAC power controller found in some PDP-11 systems. It has 6 switched power sockets. It has a small ON-OFF-ON double-throw centre-off toggle switch. With this switch in the OFF position, there will be no mains power at the power socket. Power can be\u2026","rel":"","context":"Similar post","block_context":{"text":"Similar post","link":""},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/avitech.com.au\/wp-content\/uploads\/2016\/12\/20161226_083510-Large.jpg?resize=350%2C200","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/avitech.com.au\/wp-content\/uploads\/2016\/12\/20161226_083510-Large.jpg?resize=350%2C200 1x, https:\/\/i0.wp.com\/avitech.com.au\/wp-content\/uploads\/2016\/12\/20161226_083510-Large.jpg?resize=525%2C300 1.5x, https:\/\/i0.wp.com\/avitech.com.au\/wp-content\/uploads\/2016\/12\/20161226_083510-Large.jpg?resize=700%2C400 2x, https:\/\/i0.wp.com\/avitech.com.au\/wp-content\/uploads\/2016\/12\/20161226_083510-Large.jpg?resize=1050%2C600 3x, https:\/\/i0.wp.com\/avitech.com.au\/wp-content\/uploads\/2016\/12\/20161226_083510-Large.jpg?resize=1400%2C800 4x"},"classes":[]},{"id":1887,"url":"https:\/\/avitech.com.au\/?page_id=1887","url_meta":{"origin":1983,"position":3},"title":"Digital Electronics QBUS Cabinet","author":"malcolm","date":"18-April-2017","format":false,"excerpt":"In my collection I have this rather interesting third-party QBUS system. The manufacturer was an Australian company called \"Digital Electronics\". This appears to have been specifically designed and built for lab A\/D work. The front panel has various analogue I\/O connectors. At the top of the rack is a separate\u2026","rel":"","context":"Similar post","block_context":{"text":"Similar post","link":""},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/avitech.com.au\/wp-content\/uploads\/2017\/04\/20170324_112154_1492508841761_resized.jpg?resize=350%2C200","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/avitech.com.au\/wp-content\/uploads\/2017\/04\/20170324_112154_1492508841761_resized.jpg?resize=350%2C200 1x, https:\/\/i0.wp.com\/avitech.com.au\/wp-content\/uploads\/2017\/04\/20170324_112154_1492508841761_resized.jpg?resize=525%2C300 1.5x, https:\/\/i0.wp.com\/avitech.com.au\/wp-content\/uploads\/2017\/04\/20170324_112154_1492508841761_resized.jpg?resize=700%2C400 2x, https:\/\/i0.wp.com\/avitech.com.au\/wp-content\/uploads\/2017\/04\/20170324_112154_1492508841761_resized.jpg?resize=1050%2C600 3x, https:\/\/i0.wp.com\/avitech.com.au\/wp-content\/uploads\/2017\/04\/20170324_112154_1492508841761_resized.jpg?resize=1400%2C800 4x"},"classes":[]},{"id":2660,"url":"https:\/\/avitech.com.au\/?page_id=2660","url_meta":{"origin":1983,"position":4},"title":"DEC RX33 Floppy Drive","author":"malcolm","date":"10-October-2017","format":false,"excerpt":"The RX33 is an 80-track double-sided 5.25\" floppy drive that was used by DEC in some PDP-11 and MicroVAX computers. It was also used in some other late-model DEC equipment as well, such as HSC cluster controllers. The only QBUS controller that supports the RX33 is the RQDX3. There was\u2026","rel":"","context":"Similar post","block_context":{"text":"Similar post","link":""},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/avitech.com.au\/wp-content\/uploads\/2017\/10\/20171010_185730_resized-e1507627053264.jpg?resize=350%2C200","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/avitech.com.au\/wp-content\/uploads\/2017\/10\/20171010_185730_resized-e1507627053264.jpg?resize=350%2C200 1x, https:\/\/i0.wp.com\/avitech.com.au\/wp-content\/uploads\/2017\/10\/20171010_185730_resized-e1507627053264.jpg?resize=525%2C300 1.5x, https:\/\/i0.wp.com\/avitech.com.au\/wp-content\/uploads\/2017\/10\/20171010_185730_resized-e1507627053264.jpg?resize=700%2C400 2x, https:\/\/i0.wp.com\/avitech.com.au\/wp-content\/uploads\/2017\/10\/20171010_185730_resized-e1507627053264.jpg?resize=1050%2C600 3x, https:\/\/i0.wp.com\/avitech.com.au\/wp-content\/uploads\/2017\/10\/20171010_185730_resized-e1507627053264.jpg?resize=1400%2C800 4x"},"classes":[]},{"id":34,"url":"https:\/\/avitech.com.au\/?page_id=34","url_meta":{"origin":1983,"position":5},"title":"Installing VAX BASIC 3.3","author":"malcolm","date":"4-May-2016","format":false,"excerpt":"BASIC was available from DEC as a \"layered product\" for VAX\/VMS systems. I'm running VMS 5.3 on my circa-1989 VAX. So I figured it was appropriate to install a version of BASIC from around the same time period: VAX BASIC 3.3. The first challenge was finding a copy of this\u2026","rel":"","context":"Similar post","block_context":{"text":"Similar post","link":""},"img":{"alt_text":"","src":"","width":0,"height":0},"classes":[]}],"_links":{"self":[{"href":"https:\/\/avitech.com.au\/index.php?rest_route=\/wp\/v2\/pages\/1983","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/avitech.com.au\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/avitech.com.au\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/avitech.com.au\/index.php?rest_route=\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/avitech.com.au\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1983"}],"version-history":[{"count":6,"href":"https:\/\/avitech.com.au\/index.php?rest_route=\/wp\/v2\/pages\/1983\/revisions"}],"predecessor-version":[{"id":1989,"href":"https:\/\/avitech.com.au\/index.php?rest_route=\/wp\/v2\/pages\/1983\/revisions\/1989"}],"wp:attachment":[{"href":"https:\/\/avitech.com.au\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1983"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}